Titanium Cannulated Bar ASTM F136 Orthopedic Implants

Send Inquiry
Titanium Cannulated Bar ASTM F136 Orthopedic Implants
Details
Material: Ti-6Al-4V ELI (GR23)
Standard: ASTM F136 / ISO 5832-3
Outer Diameter: 3.0mm – 8.0mm
Inner Diameter: 1.0mm – 2.5mm
Length: 20mm – 200mm
Tensile Strength: ≥860 MPa
Yield Strength: ≥795 MPa
Elongation: ≥10%
Category
Titanium Cannulated Bar
Share to
Description

What It Is

 

Hollow core design. Lets you place it over a guide wire. Solid bar can't do that.
This Titanium cannulated bar ASTM F136 orthopedic implants has a hole straight through the middle. Surgeon slides it over a wire.
ASTM F136 GR23 (Ti-6Al-4V ELI) Material. Implant-grade.means better toughness than standard Gr5. strong enough for load-bearing.

 

Technical Specifications

 

 

Parameter Value
Material Ti-6Al-4V ELI (GR23)
Standard ASTM F136 / ISO 5832-3
Outer Diameter 3.0mm – 8.0mm (custom)
Inner Diameter 1.0mm – 2.5mm (matched to OD)
Length 20mm – 200mm (custom)
Tensile Strength ≥860 MPa
Yield Strength ≥795 MPa
Elongation ≥10%
Density 4.43 g/cm³
Surface Finish Bright / Polished

 

Key Benefits

 

 

  • Cannulated design – Goes over a guide wire. Minimally invasive, precise placement.
  • High strength – GR23 titanium. Tensile ≥860 MPa. Handles load-bearing just fine.
  • Low interstitial (ELI) – Oxygen ≤0.13%. Better toughness, less risk of cracking than Gr5.
  • Biocompatible – Meets ASTM F136 and ISO 5832-3. No rejection issues.
  • Corrosion resistant – Stable oxide layer. Lasts in body fluids, seawater, chlorides.
  • Customizable – OD, ID, length, curvature. Just send your print.
  • System compatible – Works with pedicle screws, locking screws, other implant systems.

When you're sourcing Titanium cannulated bar ASTM F136 orthopedic implants, these are the specs that actually matter.

 

Main Applications

 

 

  • Orthopedic trauma – Intramedullary support for long bone fractures.
  • Spinal fixation – Posterior fixation with pedicle screws.
  • Femoral head support – Prevents collapse in early osteonecrosis (ARCO stage II).
  • Post-osteotomy support – Stabilizes bone after cutting.
  • Bone tumor reconstruction – Structural support after resection.
  • Joint fusion – Fixation support for arthrodesis procedures.

 

Why Choose Us?

 

 

Lots of titanium bar suppliers out there. Not many do cannulated bars with good concentricity. We've been supplying orthopedic implant manufacturers for years. Feedback has been solid.

Our Titanium cannulated bar ASTM F136 orthopedic implants meet ASTM F136 and ISO 5832-3. Each batch comes with MTRs. Full traceability.

Need custom sizes or curves? Just tell us. We've done everything from straight bars to patient-specific curvatures.

 

 

titanium equipment used in medical
 
Gr4 medical titanium rod
 
titanium rod in stock
 

 

Packaging & Delivery

 

 

Item Description
Packaging Individually packed. Sterile or non-sterile.
Traceability Batch number laser marked on each piece.
Lead Time 15–25 business days. Custom takes longer depending on complexity.

 

FAQ

 

 

Q: Can I get a sample for testing?

A: Yes. Hit up sales with your specs and quantity.

Q: What's the lead time for custom sizes?

A: Usually 15–25 business days. Big orders or complex curves might take longer. Send specs and we'll give you a real date.

Q: What's the difference between cannulated and solid bar?

A: Solid bar has no hole. Can't take a guide wire. Placement relies on surgeon feel. Cannulated bar has a hollow channel. Slides over a wire for better positioning. Good for minimally invasive or alignment-critical jobs. Strength is still plenty for implant use.

Q: Why Gr23 instead of Gr5 for implants?

A: Gr23 has lower oxygen (≤0.13% vs ≤0.20%). That means better toughness and fatigue strength. Less risk of hydrogen embrittlement. It's the standard for long-term implants. That's why Titanium cannulated bar ASTM F136 orthopedic implants use Gr23 instead of regular Gr5.

 

Clinical Note

 

 

Studies show cannulated titanium bars effectively support femoral heads in early osteonecrosis. In one clinical series (74 hips, ARCO stage II), the survival rate at 24 months was over 80%. The hollow design allows placement over a guide wire for precision, and the elastic modulus is close to bone - less stress shielding than stiffer materials.

 

Contact us

 

 

 

Need pricing, samples, or more info on Titanium cannulated bar ASTM F136 orthopedic implants? Reach out. We reply within 24 hours.

Email: kristy@mt-titanium.com

WhatsApp: +86-17391509251

 

Hot Tags: titanium cannulated bar astm f136 orthopedic implants, China titanium cannulated bar astm f136 orthopedic implants manufacturers, suppliers, factory, High Strength Cannulated Titanium Bar for Trauma Surgery, Hollow Titanium Bar for Dental Implant Fixtures ASTM F67, Medical Cannulated Titanium Bar for Intramedullary Nails, Ti 6Al 4V Cannulated Bar for Joint Replacement Components, titanium cannulated bar, Titanium Cannulated Bar ASTM F136 Orthopedic Implants

Send Inquiry