What it is
Dental implant fixtures go into the jawbone. Most are solid. But some designs use a hollow center.
Hollow titanium bar for dental implant fixtures ASTM F67 is the starting stock. Tube, not solid. Inner channel allows bone ingrowth. Or allows guide wire placement. Or reduces implant stiffness.
Grade 4 CP titanium. Pure titanium. No aluminum. No vanadium. ASTM F67 medical grade. Safe for permanent placement in the mouth.
Why hollow for dental implants
Solid implants work. Millions placed. But hollow designs offer advantages.
Bone grows through the hollow center. Faster osseointegration. Stronger bond. Reduces implant stiffness. Closer to natural tooth modulus.
Guide wire placement. Hollow implant goes over a wire. Wire placed first. X-ray confirms position. Implant follows exactly.
For hollow titanium bar for dental implant fixtures ASTM F67, the hollow channel is precision drilled. Centered. Smooth inside.
Why Grade 4 CP, not Ti-6Al-4V
Ti-6Al-4V is stronger. But dental implants don't need that strength. Jawbone loads are low. Grade 4 pure titanium is 550 MPa. More than enough.
Grade 4 has no aluminum. No vanadium. Some dentists prefer pure titanium for implants. Fewer theoretical concerns about metal ions.
ASTM F67 is the pure titanium medical standard. Grade 1, 2, 3, 4. Grade 4 is the strongest pure titanium.
For hollow titanium bar for dental implant fixtures ASTM F67, Grade 4 gives you strength without alloying elements.
Material specifications (Grade 4 CP, ASTM F67)
| Property | Value |
| Standard | ASTM F67 / ISO 5832-2 |
| Tensile (min) | 550 MPa |
| Yield (min) | 483 MPa |
| Elongation | ≥ 15% |
| Density | 4.51 g/cm³ |
| Purity | ≥98.8% |
Chemical limits
| Element | Max limit |
| Oxygen | 0.40% |
| Iron | 0.50% |
| Carbon | 0.08% |
| Nitrogen | 0.05% |
| Hydrogen | 0.012% |
| Titanium | ≥98.8% |
No aluminum. No vanadium. No nickel.
Common sizes for dental implant fixtures
| Outer diameter (mm) | Inner diameter (mm) | Wall thickness (mm) | Implant type |
| 3.0 | 1.5 | 0.75 | Small diameter implant |
| 3.3 | 1.8 | 0.75 | Standard anterior |
| 3.5 | 2.0 | 0.75 | Standard anterior |
| 3.8 | 2.2 | 0.80 | Universal |
| 4.0 | 2.4 | 0.80 | Standard posterior |
| 4.3 | 2.6 | 0.85 | Wide platform |
| 4.5 | 2.8 | 0.85 | Wide platform |
| 5.0 | 3.0 | 1.00 | Extra wide |
| 6.0 | 4.0 | 1.00 | Custom / special |
Wall thickness typically 0.75mm to 1.00mm. Strong enough for chewing forces. Hollow enough for bone ingrowth.
Where it goes
Dental implant fixture. The screw that goes into the jawbone. Hollow center allows bone to grow through. Faster healing. Stronger fixation.
Guide wire systems. Two-stage surgery. Wire placed first. X-ray confirms. Hollow implant goes over wire. Precise placement every time.
Platform switching implants. Hollow design allows narrower platform. More bone preservation.
For hollow titanium bar for dental implant fixtures ASTM F67, the bar gets machined into finished implants. Threads cut. Surface treated. Sterilized.
Why concentricity matters in dental implants
Dental implants are small. 3mm to 6mm diameter. The hollow center must be perfectly centered.
If the hole is off-center, wall thickness varies. Thin wall collapses during thread rolling. Weak spot fails under chewing load.
| Requirement | Tolerance |
| Concentricity | ≤ 0.05mm |
| Inner diameter | ±0.025mm |
| Outer diameter | ±0.025mm |
| Straightness | 0.1mm per 300mm |
We hold these tolerances. Every bar inspected.



Surface finish for dental implants
Dental implants contact bone and gum tissue. Smooth surface is standard. But many implants get additional surface treatment.
| Finish | Ra | Application |
| Polished | ≤ 0.2μm | As-machined, standard |
| Sandblasted | 1.0-2.0μm | Bone contact surface |
| Acid etched | 0.5-1.0μm | Osseointegration |
We supply polished bar. You apply your proprietary surface treatment. SLA. RBM. Anodized.
For hollow titanium bar for dental implant fixtures ASTM F67, polished surface is the starting point.
Manufacturing process
Solid Grade 4 bar starts as medical grade rod. Deep hole drilling. Precision drill bit through the center. High pressure coolant flushes chips.
Then centerless grinding. Outer diameter ground to tolerance. Inner diameter reamed if needed. Straightened.
Polishing. Inner and outer surfaces smooth. Final inspection. Camera down the bore. No burrs. No steps.
For hollow titanium bar for dental implant fixtures ASTM F67, the inner surface is inspected as carefully as the outer.
Thread rolling after hollowing
Dental implants need threads. External threads on the bone side. Internal threads for the abutment screw.
- Challenge: Thin wall. Rolling pressure can deform the hollow bar.
- Solution: Internal mandrel during rolling. Controlled pressure. Slow feed.
We supply hollow bar. You roll threads and machine features. Or we can supply finished implants to your print.
Traceability
Dental implants are medical devices. Class II. Full traceability required.
Every hollow titanium bar for dental implant fixtures ASTM F67 comes with:
Heat number. Mill test report. ASTM F67 cert. Chemical analysis. Mechanical test results. Diameter certification.
EN 10204 3.1 standard. 3.2 with third-party witness available.
FAQ
Q: Grade 4 CP or Grade 23 ELI for hollow implants?
A: Grade 4 CP. Dental implants don't need Ti-6Al-4V strength. Grade 4 is 550 MPa - plenty for jawbone. Pure titanium. No aluminum. No vanadium.
Q: What wall thickness for a 4.0mm implant?
A: 0.8mm. Wall thickness around 0.8mm to 1.0mm is standard. Strong enough for chewing. Hollow enough for bone ingrowth.
Q: Minimum inner diameter?
A: 1.5mm for a 3.0mm outer. Smaller possible but difficult. Drill breaks. Ask us.
Q: Can you supply bar in patient-specific lengths?
A: Yes. Cut to your fixture length. Typically 10mm to 20mm per implant. We cut, deburr, clean, and pack.
Q: Surface treatment?
A: We supply polished bar. You apply SLA, RBM, or anodized coating. Your proprietary process.
Q: Lead time?
A: Stock sizes 3-4 weeks. Custom sizes 5-6 weeks.
Q: Sample bar?
A: Yes. 200mm sample. Pay material and shipping. Credit back on first production order over $10,000.
The bottom line
Dental implants need precision. Hollow designs offer faster bone healing and guide wire placement.
Hollow titanium bar for dental implant fixtures ASTM F67 gives you the starting stock.
Grade 4 CP. ASTM F67. Pure titanium. No aluminum. No vanadium.
Concentric hollow center. Smooth inner bore. Strong enough for chewing.
For anterior implants. For posterior implants. For guide wire systems. For bone ingrowth designs.
Hollow in the middle. Strong on the outside. Pure titanium throughout.
Contact
Need a quote on hollow titanium bar for dental implant fixtures ASTM F67? Tell us outer diameter, inner diameter, length, quantity. We'll reply within 24 hours.
Email: kristy@mt-titanium.com
WhatsApp: +86-17391509251
Hot Tags: hollow titanium bar for dental implant fixtures astm f67, China hollow titanium bar for dental implant fixtures astm f67 manufacturers, suppliers, factory, Cannulated Titanium Bar for Surgical Implants, High Strength Cannulated Titanium Bar for Trauma Surgery, Precision Cannulated Titanium Bar, Ti 6Al 4V Cannulated Bar for Joint Replacement Components, Ti‑6Al‑4V Cannulated Bar for Joint Replacement Components, Titanium Cannulated Bar ASTM F136 Orthopedic Implants