ASTM F67 Description
ASTM F67 isn't just a spec number. It's the line between material that can go into a human body and material that can't. Industrial titanium is cheap and available. Implant-grade titanium is controlled, tested, and traceable. The FDA has recognized ASTM F67 as a consensus standard for surgical implant applications since the late 1990s, and the current revision F67-24 remains on the recognized list.
The spec covers four grades of unalloyed titanium - Grade 1 through Grade 4 - in strip, sheet, plate, bar, billet, forging, and wire form. Each grade has a different balance of strength and ductility. Grade 1 bends the easiest. Grade 4 carries the most load. Picking the wrong one isn't a cost issue. It's a design failure.
Product Specifications
|
Grade |
UNS |
Tensile (min) |
Yield (min) |
Elongation |
Reduction of Area |
|
Grade 1 |
R50250 |
240 MPa |
170 MPa |
24% |
30% |
|
Grade 2 |
R50400 |
345 MPa |
275 MPa |
20% |
30% |
|
Grade 3 |
R50550 |
450 MPa |
380 MPa |
18% |
30% |
|
Grade 4 |
R50700 |
550 MPa |
483 MPa |
15% |
25% |
Chemical Composition (ASTM F67, max limits)
|
Element |
Gr1 |
Gr2 |
Gr3 |
Gr4 |
|
Oxygen |
0.18 |
0.25 |
0.35 |
0.40 |
|
Iron |
0.20 |
0.30 |
0.30 |
0.50 |
|
Carbon |
0.08 |
0.08 |
0.08 |
0.08 |
|
Nitrogen |
0.03 |
0.03 |
0.05 |
0.05 |
|
Hydrogen |
0.015 |
0.015 |
0.015 |
0.015 |
|
Titanium |
Balance |
Balance |
Balance |
Balance |
The oxygen numbers tell the story. Grade 1 at 0.18% oxygen is soft and formable. Grade 4 at 0.40% oxygen is nearly double the strength but half the ductility. That trade-off is why Grade 4 is used for dental fixtures that need osseointegration and load capacity, while Grade 1 is used for cranial mesh that surgeons shape by hand in the operating room.
Production Route - From Sponge to Surgical Rod
Implant-grade titanium doesn't start as metal. It starts as titanium sponge - porous, grey, and chemically raw. That sponge goes through a chain of steps that turns it into a certified surgical implant rod. Every step matters. Any shortcut shows up in the final microstructure.
Titanium sponge is the base. It's produced from rutile or ilmenite ore through the Kroll process. The sponge is pressed into a consumable electrode - often called a pizza electrode because of its disc shape - and welded together into a column. That electrode goes into a vacuum arc remelting furnace. The arc melts the electrode. Molten titanium drips into a water-cooled copper crucible. Impurities either vaporize or float out. The ingot that forms is the first solid titanium in the chain.
That ingot gets forged. Forging breaks up the cast structure. It closes porosity. It refines grain size. The result is a rod billet - a semi-finished bar ready for further processing. The billet then goes to hot rolling. Temperature is controlled. Reduction ratios are controlled. The goal is uniform deformation through the cross-section. After rolling, the rod is pickled. Acid bath removes the oxide scale that formed during hot working. Pickling also exposes surface defects so they can be caught before machining.
Machining comes next. The rod is turned or centerless ground to the specified diameter. Tolerance tightens. Surface finish improves. Straightness is corrected. Then polishing. Polished rod has a smooth surface for tissue contact applications. It also removes any remaining surface imperfections that could act as fatigue crack initiation sites.
The final product is titanium rod - certified, tested, and traceable. Every step from sponge to finished rod is documented. The heat number stays with the material through every process. That's how implant-grade traceability works.

|
Step |
What Happens |
Why It Matters |
|
Titanium sponge |
Kroll process from ore |
Base material. Chemistry starts here. |
|
Pizza electrode |
Sponge pressed and welded |
Consumable electrode for melting. |
|
Smelting |
Vacuum arc remelting |
Removes impurities. Homogenizes chemistry. |
|
Forging |
Hot deformation |
Breaks cast structure. Refines grain. |
|
Rod billet |
Semi-finished bar |
Intermediate product. Ready for rolling. |
|
Hot rolling |
Controlled deformation |
Shapes and reduces diameter. |
|
Pickling |
Acid bath |
Removes oxide scale. Reveals surface defects. |
|
Machining |
Turning or centerless grinding |
Achieves diameter tolerance. |
|
Polishing |
Surface finishing |
Smooth surface. Removes crack initiation sites. |
|
Titanium Rod |
Final product |
Certified. Tested. Traceable. |
Inspection
ASTM F67 requires more than a basic mill certificate. Each lot must be tested for chemical composition per ASTM E1409 (oxygen and nitrogen), E1941 (carbon), or E2371 (plasma emission spectrometry). Mechanical properties - tensile, yield, elongation, reduction of area - are tested per lot.
For larger diameter bar, ultrasonic inspection detects internal defects like voids or inclusions that could become crack initiation sites. Chinese standard GB/T 40324 covers focused ultrasonic testing for large diameter round bars (≥100mm) made from titanium alloys and superalloys.
Grain size and microstructure are checked if specified. Surface condition is visually inspected for cracks, seams, laps, or scale.
Documentation
Every lot ships with a Mill Test Report (MTR) documenting heat number, chemical analysis, and mechanical test results. The MTR traces back to the original melt.
EN 10204 3.1 is standard. 3.2 with third-party witness is available for OEMs that need independent verification. For ISO 13485 quality systems, the documentation package must link each finished implant to the specific material lot it was machined from.
Traceability
Implant-grade titanium requires full traceability from melt to finished device. That's not optional for regulatory submissions. FDA recognized ASTM F67 as a consensus standard for surgical implants as early as 1999. The current version, F67-24, remains on the FDA recognition list.
Traceability means each rod carries a heat number that links to the original titanium sponge. Batch records show melting, forging, and drawing history. If a problem surfaces later, the material can be traced and affected devices identified.
Customization
Standard diameters run 3mm to 50mm. Larger sizes available as forged rod up to 100mm or beyond, depending on mill capability. Lengths are typically 500mm to 3000mm, but cut-to-length is standard - send a cut list and the rod arrives deburred and packaged.
Diameter tolerance follows ISO 286-2. For Swiss machining, h7 is common. For precision surgical instruments, h6. Centerless ground is the default finish.
Anodizing, passivation, and clean-room packaging are available on request.


Grade Selection - What Goes Where
Grade 1 is the softest and most formable. Used for craniofacial plates, mesh for bone reconstruction, and non-load-bearing dental components. It bends by hand in the OR without cracking.
Grade 2 is the general-purpose medical grade. Used for healing abutments, transfer copings, and components where moderate strength is sufficient. It's also the most commonly specified grade for dental implant fixtures in some markets.
Grade 4 is the strongest pure titanium grade. Used for dental implant fixtures that need osseointegration and some load-bearing capability, and for orthopedic components where Ti-6Al-4V isn't required.
None of the pure titanium grades substitute for Grade 23 ELI in high-stress applications like spinal rods or hip stems. Grade 4 pure titanium has 550 MPa tensile; Grade 23 ELI has 860 MPa. The gap matters when cyclic loading is involved.
FAQ

01.What's the difference between ASTM F67 and ASTM F136?
02.Can I use ASTM B348 industrial rod for implants?
03.What diameter tolerance can you hold?
04.What documentation comes with the rod?
05.Lead time?
ASTM F67 is the standard that makes pure titanium implant-grade. Grade 1 for formability. Grade 2 for general medical. Grade 4 for strength. ASTM F67 Pure Titanium Rod Gr1 Gr2 Gr3 Gr4 Surgical Implant delivers the certified material that surgical device manufacturers build on.
Contact
Need a quote on ASTM F67 Pure Titanium Rod Gr1 Gr2 Gr3 Gr4 Surgical Implant? Tell us grade, diameter, length, quantity, and surface finish. Include any cert requirements. We'll reply within 24 hours.
Email: kristy@mt-titanium.com
WhatsApp: +86-17391509251
Hot Tags: astm f67 pure titanium rod gr1 gr2 gr3 gr4 surgical implant, China astm f67 pure titanium rod gr1 gr2 gr3 gr4 surgical implant manufacturers, suppliers, factory, Biocompatible Titanium Rod for Surgical Implants, High Strength Medical Titanium Rod for Prosthetics, Medical Titanium Alloy Rods for Orthopedic Screws, Ti 6Al 4V ELI Medical Rod for Pediatric Orthopedics, Titanium Alloy Rods Comply With The ASTM F67 Standard, Trauma Surgery Support Titanium Rod Medical Grade