Ti‑6Al‑4V ELI Implant Titanium Wire for Orthopedics

Send Inquiry
Ti‑6Al‑4V ELI Implant Titanium Wire for Orthopedics
Details
Material: Ti-6Al-4V ELI (Grade 23)
Standard: ASTM F136 / ISO 5832-3
Diameter: 0.5mm – 3.5mm
Length: 1000mm – 5000mm (straight) or coil
Surface: Polished (Ra ≤ 0.2μm) or ground
Category
Medical Titanium Wire
Share to
Description

What it is

 

Orthopedic surgery needs wire. Cerclage around bone. Tension bands through drill holes. Cables around fractures. Sublaminar wires in spine.

Ti‑6Al‑4V ELI implant titanium wire for orthopedics is made for those jobs. Strong enough to hold bone fragments. Flexible enough to wrap around bone. Safe enough to stay inside forever.

Not stainless. Not pure titanium. Grade 23 ELI. High strength. High fatigue life. No nickel. Biocompatible.

 

Why ELI, not regular Grade 5 

 

Regular Grade 5 (Ti-6Al-4V) is strong. Tensile 895 MPa. But it has higher oxygen. Higher iron. Lower toughness.

ELI means Extra Low Interstitial. Lower oxygen. Lower iron. Better fatigue life. Higher fracture toughness.

Property Grade 23 ELI Regular Grade 5
Oxygen (max) 0.13% 0.20%
Iron (max) 0.25% 0.30%
Tensile strength 860-1000 MPa 895-1100 MPa
Fatigue life Better Good
Fracture toughness Higher Lower
Implant use Yes No (commercial)

For Ti‑6Al‑4V ELI implant titanium wire for orthopedics, ELI is the medical standard. ASTM F136. Regular Grade 5 is ASTM B348 - commercial grade. Not approved for implants.

 

Material specifications 

 

Property Value
Standard ASTM F136 / ISO 5832-3
UNS Number R56401
Common name Grade 23
Tensile (min) 860 MPa
Yield (min) 795 MPa
Elongation (min) 10%
Reduction of area (min) 25%
Density 4.43 g/cm³
Modulus 110 GPa

 

Chemical composition (max limits)

Element ASTM F136
Oxygen 0.13%
Iron 0.25%
Carbon 0.08%
Nitrogen 0.05%
Hydrogen 0.012%
Aluminum 5.5 – 6.5%
Vanadium 3.5 – 4.5%
Titanium Balance

 

Common diameters for orthopedic applications 

 

Diameter (mm) Application Typical use
0.5 – 0.8 Small bone cerclage Hand, foot, pediatric
0.8 – 1.0 Tension band Patella, olecranon
1.0 – 1.2 Cerclage wire Humerus, tibia
1.2 – 1.5 Sublaminar wire Spine
1.5 – 2.0 Cable wire Femur, revision surgery
2.0 – 3.5 Heavy cerclage Trauma, periprosthetic

 

Where it goes 

 

  • Cerclage wire wraps around bone. Fractured bone has cracks. Wire goes around the outside. Squeezes the pieces together. Used for long bones. Femur. Tibia. Humerus.

  • Tension band wire. For fractures that pull apart. Patella. Olecranon. Wire goes through drill holes. Figure eight pattern. Pulls the fragments together.

  • Sublaminar wire. Spine surgery. Wire passes under the lamina. Wraps around the rod. Tightened. Holds the spinal construct.

  • Cable systems. Multiple strands braided together. Stronger than single wire. Used for periprosthetic fractures. Long spiral fractures.

For Ti‑6Al‑4V ELI implant titanium wire for orthopedics, each application requires high strength and good fatigue life. The wire stays in the patient forever.

 

Why strength matters in orthopedic wire 

 

Cerclage wire holds bone fragments under tension. A femur sees high loads. Walking. Stairs. The wire has to hold.

Wire type Tensile strength Max load for 1.2mm wire
Grade 1 pure titanium 240 MPa ~270 N
Grade 4 pure titanium 550 MPa ~620 N
Ti-6Al-4V ELI 860+ MPa ~970 N

For Ti‑6Al‑4V ELI implant titanium wire for orthopedics, strength means security. The wire won't break under load.

 

Fatigue life - the real concern 

 

Bones move. Patients walk. The wire cycles millions of times.

Activity Cycles per year (approx)
Normal walking 1.5 million
Active patient 2-3 million
Heavy activity 5 million+

ELI chemistry improves fatigue life. Lower oxygen means fewer crack initiation sites.

Material Fatigue limit (10^7 cycles)
Grade 23 ELI 500-600 MPa
Grade 4 CP 300-350 MPa
Grade 2 CP 200-250 MPa

For Ti‑6Al‑4V ELI implant titanium wire for orthopedics, fatigue life is not academic. It's how long the wire will hold before the bone heals.

 

Surface finish 

 

Orthopedic wire contacts bone and soft tissue. Smooth surface reduces irritation.

Finish Ra Best for
Polished ≤ 0.2μm Tissue contact, standard
Ground ≤ 0.4μm Internal, under plates

For Ti‑6Al‑4V ELI implant titanium wire for orthopedics, polished is standard. Smooth. Clean. Ready for the OR.

 

Wire handling for surgery 

 

Surgeons twist cerclage wire. Loop it around bone. Tighten with tensioner. Cut the ends.

The wire needs ductility. Not brittle. Must twist without cracking.

Test Requirement
Twist test 10 twists, no cracks
Bend test 180° bend, no cracks
Tensile 860+ MPa

Our wire passes all three. Strong enough. Ductile enough.

 

Cerclage technique 

 

Cerclage wire passes around the bone. Often with a passer tool. Wire loops around. Both ends come out. Twisted together. Tightened. Cut.

For Ti‑6Al‑4V ELI implant titanium wire for orthopedics, the wire needs consistent diameter. Smooth surface. No burrs. No scratches.

Diameter variation causes uneven twisting. Too thin, the wire breaks. Too thick, the twist is loose.

We hold ±0.02mm tolerance on diameter.

 

Tension band technique 

 

Drill holes across the fracture. Pass wire through. Cross on the tension side. Tighten.

Patella fracture. Olecranon fracture. The wire turns tensile force into compression.

Wire needs good elongation. 10% minimum. Can be tied in a knot without breaking.

Grade 23 ELI gives you 10-15% elongation. Enough for surgical knots.

 

Sublaminar wire in spine 

 

Wire passes under the lamina. Around the rod. Tightened.

Tight spaces. Wire must be flexible enough to pass. Strong enough to hold.

1.2mm to 1.5mm diameter is standard. Polished surface helps passage.

 

Coating options 

 

Some orthopedic wire needs coating. For visibility. For imaging.

Coating Benefit Application
None Standard Most cerclage
PTFE Low friction Cable systems
Color anodized Identification Sublaminar (size coding)

We supply uncoated wire. Coating applied by device manufacturer.

 

Traceability 

 

Orthopedic wire is a medical device. Full traceability required.

Every Ti‑6Al‑4V ELI implant titanium wire for orthopedics comes with:

Document Provided
Heat number Yes
Mill test report Yes
ASTM F136 cert Yes
Chemical analysis Yes
Mechanical test results Yes
Diameter certification Yes

EN 10204 3.1 standard. 3.2 available with third-party witness.

 

FAQ 

 

Q: Grade 23 ELI or Grade 4 for cerclage wire?

A: Grade 23 ELI. Grade 4 pure titanium is 550 MPa. Too weak for load-bearing cerclage. ELI gives you 860+ MPa.

Q: What diameter for patella tension band?

A: 1.0mm to 1.2mm. Strong enough for knee. Thin enough to pass through drill holes.

Q: What diameter for femoral cerclage?

A: 1.5mm to 2.0mm. Femur sees high loads. Larger diameter needed.

Q: Polished or ground for sublaminar wire?

A: Polished. Smoother surface passes under lamina with less trauma.

Q: Can you supply wire in coils for automated cutting?

A: Yes. Coils up to 5kg. Straight lengths also available.

Q: Lead time?

A: 

Order type Lead time
Stock diameters (0.8mm – 1.5mm) 7-10 days
Non-stock sizes 3-5 weeks
Custom coils Add 1 week

 

Q: Sample wire for evaluation?

A: Yes. 1 meter sample. Pay shipping. Material free for evaluation. Credit back on first production order over $10,000.

Q: Packaging?

A: Straight lengths in sealed tubes. Coils on spools in anti-static bags. Labels show material, diameter, length, heat number, ASTM F136.

 

 

The bottom line 

 

Orthopedic wire holds bone together. Cerclage. Tension band. Sublaminar. The wire stays in the patient forever.

Ti‑6Al‑4V ELI implant titanium wire for orthopedics delivers the strength and safety you need.

Feature Benefit
Grade 23 ELI 860+ MPa tensile
ASTM F136 Medical implant standard
No nickel Safe for long-term implants
Polished surface Smooth, tissue friendly
±0.02mm tolerance Consistent twisting
Good fatigue life Holds until bone heals

For patella. For femur. For spine. For trauma.

Strong enough to hold. Flexible enough to tie.

 

Contact

 

 

 

Need a quote on Ti‑6Al‑4V ELI implant titanium wire for orthopedics? Tell us diameter, length (straight or coil), quantity, and any surface finish requirements. We'll reply within 24 hours.

Email: kristy@mt-titanium.com

WhatsApp: +86-17391509251

 

 

Hot Tags: ti‑6al‑4v eli implant titanium wire for orthopedics, China ti‑6al‑4v eli implant titanium wire for orthopedics manufacturers, suppliers, factory, Flexible Medical Titanium Wire for Minimally Invasive Surgery, Medical Grade Titanium Wire for Surgical Sutures, Medical Titanium Wire ASTM F67 Orthopedic Cerclage, Ti 6Al 4V ELI Implant Titanium Wire for Orthopedics, Ti‑6Al‑4V ELI Implant Titanium Wire for Orthopedics, Titanium Surgical Wire ASTM F136 Sternal Closure

Send Inquiry