What it is
Orthopedic surgery needs wire. Cerclage around bone. Tension bands through drill holes. Cables around fractures. Sublaminar wires in spine.
Ti‑6Al‑4V ELI implant titanium wire for orthopedics is made for those jobs. Strong enough to hold bone fragments. Flexible enough to wrap around bone. Safe enough to stay inside forever.
Not stainless. Not pure titanium. Grade 23 ELI. High strength. High fatigue life. No nickel. Biocompatible.
Why ELI, not regular Grade 5
Regular Grade 5 (Ti-6Al-4V) is strong. Tensile 895 MPa. But it has higher oxygen. Higher iron. Lower toughness.
ELI means Extra Low Interstitial. Lower oxygen. Lower iron. Better fatigue life. Higher fracture toughness.
| Property | Grade 23 ELI | Regular Grade 5 |
| Oxygen (max) | 0.13% | 0.20% |
| Iron (max) | 0.25% | 0.30% |
| Tensile strength | 860-1000 MPa | 895-1100 MPa |
| Fatigue life | Better | Good |
| Fracture toughness | Higher | Lower |
| Implant use | Yes | No (commercial) |
For Ti‑6Al‑4V ELI implant titanium wire for orthopedics, ELI is the medical standard. ASTM F136. Regular Grade 5 is ASTM B348 - commercial grade. Not approved for implants.
Material specifications
| Property | Value |
| Standard | ASTM F136 / ISO 5832-3 |
| UNS Number | R56401 |
| Common name | Grade 23 |
| Tensile (min) | 860 MPa |
| Yield (min) | 795 MPa |
| Elongation (min) | 10% |
| Reduction of area (min) | 25% |
| Density | 4.43 g/cm³ |
| Modulus | 110 GPa |
Chemical composition (max limits)
| Element | ASTM F136 |
| Oxygen | 0.13% |
| Iron | 0.25% |
| Carbon | 0.08% |
| Nitrogen | 0.05% |
| Hydrogen | 0.012% |
| Aluminum | 5.5 – 6.5% |
| Vanadium | 3.5 – 4.5% |
| Titanium | Balance |
Common diameters for orthopedic applications
| Diameter (mm) | Application | Typical use |
| 0.5 – 0.8 | Small bone cerclage | Hand, foot, pediatric |
| 0.8 – 1.0 | Tension band | Patella, olecranon |
| 1.0 – 1.2 | Cerclage wire | Humerus, tibia |
| 1.2 – 1.5 | Sublaminar wire | Spine |
| 1.5 – 2.0 | Cable wire | Femur, revision surgery |
| 2.0 – 3.5 | Heavy cerclage | Trauma, periprosthetic |
Where it goes
-
Cerclage wire wraps around bone. Fractured bone has cracks. Wire goes around the outside. Squeezes the pieces together. Used for long bones. Femur. Tibia. Humerus.
-
Tension band wire. For fractures that pull apart. Patella. Olecranon. Wire goes through drill holes. Figure eight pattern. Pulls the fragments together.
-
Sublaminar wire. Spine surgery. Wire passes under the lamina. Wraps around the rod. Tightened. Holds the spinal construct.
-
Cable systems. Multiple strands braided together. Stronger than single wire. Used for periprosthetic fractures. Long spiral fractures.
For Ti‑6Al‑4V ELI implant titanium wire for orthopedics, each application requires high strength and good fatigue life. The wire stays in the patient forever.
Why strength matters in orthopedic wire
Cerclage wire holds bone fragments under tension. A femur sees high loads. Walking. Stairs. The wire has to hold.
| Wire type | Tensile strength | Max load for 1.2mm wire |
| Grade 1 pure titanium | 240 MPa | ~270 N |
| Grade 4 pure titanium | 550 MPa | ~620 N |
| Ti-6Al-4V ELI | 860+ MPa | ~970 N |
For Ti‑6Al‑4V ELI implant titanium wire for orthopedics, strength means security. The wire won't break under load.
Fatigue life - the real concern
Bones move. Patients walk. The wire cycles millions of times.
| Activity | Cycles per year (approx) |
| Normal walking | 1.5 million |
| Active patient | 2-3 million |
| Heavy activity | 5 million+ |
ELI chemistry improves fatigue life. Lower oxygen means fewer crack initiation sites.
| Material | Fatigue limit (10^7 cycles) |
| Grade 23 ELI | 500-600 MPa |
| Grade 4 CP | 300-350 MPa |
| Grade 2 CP | 200-250 MPa |
For Ti‑6Al‑4V ELI implant titanium wire for orthopedics, fatigue life is not academic. It's how long the wire will hold before the bone heals.
Surface finish
Orthopedic wire contacts bone and soft tissue. Smooth surface reduces irritation.
| Finish | Ra | Best for |
| Polished | ≤ 0.2μm | Tissue contact, standard |
| Ground | ≤ 0.4μm | Internal, under plates |
For Ti‑6Al‑4V ELI implant titanium wire for orthopedics, polished is standard. Smooth. Clean. Ready for the OR.
Wire handling for surgery
Surgeons twist cerclage wire. Loop it around bone. Tighten with tensioner. Cut the ends.
The wire needs ductility. Not brittle. Must twist without cracking.
| Test | Requirement |
| Twist test | 10 twists, no cracks |
| Bend test | 180° bend, no cracks |
| Tensile | 860+ MPa |
Our wire passes all three. Strong enough. Ductile enough.
Cerclage technique
Cerclage wire passes around the bone. Often with a passer tool. Wire loops around. Both ends come out. Twisted together. Tightened. Cut.
For Ti‑6Al‑4V ELI implant titanium wire for orthopedics, the wire needs consistent diameter. Smooth surface. No burrs. No scratches.
Diameter variation causes uneven twisting. Too thin, the wire breaks. Too thick, the twist is loose.
We hold ±0.02mm tolerance on diameter.
Tension band technique
Drill holes across the fracture. Pass wire through. Cross on the tension side. Tighten.
Patella fracture. Olecranon fracture. The wire turns tensile force into compression.
Wire needs good elongation. 10% minimum. Can be tied in a knot without breaking.
Grade 23 ELI gives you 10-15% elongation. Enough for surgical knots.
Sublaminar wire in spine
Wire passes under the lamina. Around the rod. Tightened.
Tight spaces. Wire must be flexible enough to pass. Strong enough to hold.
1.2mm to 1.5mm diameter is standard. Polished surface helps passage.
Coating options
Some orthopedic wire needs coating. For visibility. For imaging.
| Coating | Benefit | Application |
| None | Standard | Most cerclage |
| PTFE | Low friction | Cable systems |
| Color anodized | Identification | Sublaminar (size coding) |
We supply uncoated wire. Coating applied by device manufacturer.
Traceability
Orthopedic wire is a medical device. Full traceability required.
Every Ti‑6Al‑4V ELI implant titanium wire for orthopedics comes with:
| Document | Provided |
| Heat number | Yes |
| Mill test report | Yes |
| ASTM F136 cert | Yes |
| Chemical analysis | Yes |
| Mechanical test results | Yes |
| Diameter certification | Yes |
EN 10204 3.1 standard. 3.2 available with third-party witness.
FAQ
Q: Grade 23 ELI or Grade 4 for cerclage wire?
A: Grade 23 ELI. Grade 4 pure titanium is 550 MPa. Too weak for load-bearing cerclage. ELI gives you 860+ MPa.
Q: What diameter for patella tension band?
A: 1.0mm to 1.2mm. Strong enough for knee. Thin enough to pass through drill holes.
Q: What diameter for femoral cerclage?
A: 1.5mm to 2.0mm. Femur sees high loads. Larger diameter needed.
Q: Polished or ground for sublaminar wire?
A: Polished. Smoother surface passes under lamina with less trauma.
Q: Can you supply wire in coils for automated cutting?
A: Yes. Coils up to 5kg. Straight lengths also available.
Q: Lead time?
A:
| Order type | Lead time |
| Stock diameters (0.8mm – 1.5mm) | 7-10 days |
| Non-stock sizes | 3-5 weeks |
| Custom coils | Add 1 week |
Q: Sample wire for evaluation?
A: Yes. 1 meter sample. Pay shipping. Material free for evaluation. Credit back on first production order over $10,000.
Q: Packaging?
A: Straight lengths in sealed tubes. Coils on spools in anti-static bags. Labels show material, diameter, length, heat number, ASTM F136.
The bottom line
Orthopedic wire holds bone together. Cerclage. Tension band. Sublaminar. The wire stays in the patient forever.
Ti‑6Al‑4V ELI implant titanium wire for orthopedics delivers the strength and safety you need.
| Feature | Benefit |
| Grade 23 ELI | 860+ MPa tensile |
| ASTM F136 | Medical implant standard |
| No nickel | Safe for long-term implants |
| Polished surface | Smooth, tissue friendly |
| ±0.02mm tolerance | Consistent twisting |
| Good fatigue life | Holds until bone heals |
For patella. For femur. For spine. For trauma.
Strong enough to hold. Flexible enough to tie.
Contact
Need a quote on Ti‑6Al‑4V ELI implant titanium wire for orthopedics? Tell us diameter, length (straight or coil), quantity, and any surface finish requirements. We'll reply within 24 hours.
Email: kristy@mt-titanium.com
WhatsApp: +86-17391509251
Hot Tags: ti‑6al‑4v eli implant titanium wire for orthopedics, China ti‑6al‑4v eli implant titanium wire for orthopedics manufacturers, suppliers, factory, Flexible Medical Titanium Wire for Minimally Invasive Surgery, Medical Grade Titanium Wire for Surgical Sutures, Medical Titanium Wire ASTM F67 Orthopedic Cerclage, Ti 6Al 4V ELI Implant Titanium Wire for Orthopedics, Ti‑6Al‑4V ELI Implant Titanium Wire for Orthopedics, Titanium Surgical Wire ASTM F136 Sternal Closure