What this wire is for
Cardiovascular procedures need guide wires. The wire goes into the artery. Past the blockage. Over the wire, the balloon goes. Then the stent.
Cardiovascular stent titanium guide wire Nitinol is what interventional cardiologists use. The wire has to be flexible enough to navigate tortuous arteries. Strong enough to push. Visible under X-ray.
Nitinol (Nickel-Titanium) gives you superelasticity. Titanium gives you biocompatibility and MRI compatibility. Guide wires often use Nitinol core with titanium or polymer coating.
Stent delivery. Angioplasty. Peripheral interventions. Neurovascular procedures.
Why Nitinol for guide wires
Stainless steel guide wires work. But stainless is stiff. It doesn't like to bend around tight corners.
Nitinol is superelastic. It bends. Then it goes back to straight. No kink. No permanent deformation.
For cardiovascular stent titanium guide wire Nitinol, the superelasticity lets the wire navigate coronary arteries. Around bends. Through tight lesions. Back to straight when released.
Titanium versions (non-Nitinol) use Ti-6Al-4V ELI. Also flexible. But less superelastic. Used for less tortuous anatomy.
Nitinol vs pure titanium guide wire
| Feature | Nitinol | Ti-6Al-4V ELI |
| Superelasticity | Yes | No |
| Kink resistance | Excellent | Good |
| Stiffness (modulus) | ~40 GPa | ~110 GPa |
| MRI artifact | Minimal | Minimal |
| Nickel content | 50-55% | 0% |
| Best for | Tortuous vessels | Straight or mild curves |
Nitinol contains nickel. About 50%. Most patients tolerate it. No allergic reactions reported for Nitinol implants. But some hospitals still prefer nickel-free.
For cardiovascular stent titanium guide wire Nitinol, the superelasticity is the main advantage. For nickel-free applications, use Ti-6Al-4V ELI wire.
Technical specs (Nitinol)
| Property | Value |
| Standard | ASTM F2063 |
| Composition | 54-57% Ni, balance Ti |
| Austenite finish temperature (Af) | 15°C – 35°C (body active) |
| Superelastic strain | 6-8% |
| Modulus (austenite) | ~40 GPa |
| Tensile strength | 1000 – 1400 MPa |
| Elongation | ≥ 10% |
Common diameters for guide wires
| Diameter (mm) | Inch | Use |
| 0.35 | 0.014" | Coronary guide wire. Most common. |
| 0.46 | 0.018" | Peripheral guide wire. |
| 0.53 | 0.021" | Larger vessels. |
| 0.64 | 0.025" | Heavy support. |
| 0.89 | 0.035" | Diagnostic catheters. |
| 0.2 – 0.3 | - | Neurovascular. Very small vessels. |
0.35mm (0.014") is the standard coronary guide wire diameter.
Where this wire goes
Cardiac catheterization lab. The patient has a blocked coronary artery. The interventional cardiologist inserts the guide wire.
Cardiovascular stent titanium guide wire Nitinol goes in through the femoral or radial artery. Up the aorta. Into the coronary artery. Past the blockage.
The wire tip is soft. Prevents vessel damage. The shaft is stiffer. Pushes the wire forward.
Over the wire: balloon catheter. Inflate. Then stent delivery. Deploy. Withdraw wire.
Neurovascular. Brain arteries. Smaller wires. 0.2mm to 0.3mm. Same superelasticity.
Peripheral. Leg arteries. Larger wires. 0.46mm to 0.64mm.
Each procedure uses multiple wires. Different stiffness. Different tip shapes.
Core wire and coating
Most guide wires are not solid Nitinol. They have a core wire. Coating on the outside.
Cardiovascular stent titanium guide wire Nitinol often uses:
- Nitinol core. Superelastic. Kink resistant.
- PTFE coating. Low friction. Slides through catheters.
- Hydrophilic coating. Very slippery when wet. For tight lesions.
- Titanium or polymer jacket. For MRI visibility. For nickel-free surface.
- We supply core wire. Catheter manufacturers apply their own coating.
Surface finish
Guide wire surface affects friction. Friction affects pushability. Too much friction, the wire sticks.
Polished. Ra ≤ 0.1μm. Smooth. Low friction.
Ground. Ra ≤ 0.2μm. Also smooth.
PTFE coated. Very low friction. Standard for coronary guide wires.
For cardiovascular stent titanium guide wire Nitinol, polished or PTFE coated is standard. Uncoated wire is for manufacturing.
MRI compatibility
Cardiovascular patients need MRI follow-up. Stents. Guide wires left in place? Guide wires are removed after the procedure. Not implanted.
But the wire may be in the patient during MRI if the scan happens during the procedure. Rare.
Cardiovascular stent titanium guide wire Nitinol is MRI conditional. Minimal artifact. Non-ferromagnetic. Safe for 1.5T and 3T MRI.
Titanium guide wires (non-Nitinol) are even safer. Zero nickel. Zero artifact.
Torque and tip shape
- Guide wires need torque. The doctor twists the wire outside the patient. The tip turns inside the vessel.
- Good torque response means 1:1 rotation. Twist the handle. The tip moves the same amount.
- Our wire has consistent diameter. Smooth surface. Allows torque coating to bond properly.
- Tip shapes: Straight. J-tip. Angled. Shaping ribbon inside the distal tip. We supply core wire. You shape the tip.
Traceability and certification
Medical grade. Full traceability.
Every spool of cardiovascular stent titanium guide wire Nitinol comes with:
Heat number. Mill test report. ASTM F2063, F136, or F67 cert. Chemical analysis. Mechanical test results. Transformation temperature (Nitinol). Diameter certification.
EN 10204 3.1 standard. 3.2 available.
FAQ
Q: Nitinol or Ti-6Al-4V ELI for guide wire core?
A: Nitinol for tortuous anatomy. Coronary. Neurovascular. Superelasticity prevents kinking. Ti-6Al-4V ELI for straight vessels. Peripheral. No nickel.
Q: What is the transformation temperature (Af) of your Nitinol?
A: We supply Nitinol with Af 15°C to 35°C. Active at body temperature (37°C). Lower Af available on request.
Q: Can you supply Nitinol in straight lengths?
A: Yes. Straight lengths up to 3000mm. Also spools. Straight lengths for guide wire manufacturing.
Q: What certifications come with the wire?
A: ASTM F2063 cert for Nitinol. MTR with heat number. Transformation temperature report. Diameter cert. EN 10204 3.1.
Q: Lead time for guide wire stock?
A: Stock diameters (0.35mm, 0.46mm, 0.53mm) ship in 7-10 days with paperwork. Non-stock sizes take 3-5 weeks.
The bottom line
Cardiovascular guide wires need to be flexible, strong, and kink-resistant.
Cardiovascular stent titanium guide wire Nitinol gives you that. Superelasticity. Kink resistance. MRI safe.
0.35mm for coronary. Nitinol core. Polished or PTFE coated.
ASTM F2063. Full traceability.
For coronary angioplasty. For peripheral interventions. For neurovascular procedures.
Contact
Need a quote on cardiovascular stent titanium guide wire Nitinol? Send diameter, length (straight or spool), quantity, and any material spec (Nitinol, Ti-6Al-4V ELI, or CP Grade 2). We'll reply within 24 hours.
Email: kristy@mt-titanium.com
WhatsApp: +86-17391509251
Hot Tags: cardiovascular stent titanium guide wire nitinol, China cardiovascular stent titanium guide wire nitinol manufacturers, suppliers, factory, Flexible Medical Titanium Wire for Minimally Invasive Surgery, High Purity Medical Titanium Wire for Implantable Devices, medical titanium wire, Medical Titanium Wire ASTM F67 Orthopedic Cerclage, Ti‑6Al‑4V ELI Implant Titanium Wire for Orthopedics, Titanium Wire for Dental Implants