Medical titanium wire comes in diameters from 0.05mm to 6.0mm, in half a dozen alloys, multiple tempers, and various surface finishes. The right combination depends entirely on your application. The wrong combination will show up on your machining line or in your fatigue data.
We have been supplying this stuff for years. Here is the practical breakdown - no theory, no generic descriptions. Just what we actually see in the market and on the shop floor.

What "Medical Titanium Wire" Even Means
There is no single product called medical titanium wire. The category covers diameters from 0.05mm (fine enough for neurovascular guidewires) up to 6.0mm (heavy-gauge wire for structural fixation or forming into Kirschner wires). The alloys, surface finishes, mechanical properties, and delivery forms vary dramatically depending on the end use.
|
What You Are Making |
Typical Diameter |
Alloy & Temper |
Why It Matters |
|
Neurovascular guidewires, cochlear leads |
0.05–0.30mm |
CP Grade 1 or 2, fully annealed |
Extreme ductility, no work-hardening during coiling, non-magnetic for MRI compatibility |
|
Orthodontic archwires |
0.30–0.80mm |
CP Grade 2, or β-titanium (TMA) |
Springback behavior, consistent force delivery over months of activation |
|
Suture anchors, small bone screws (wire blanks) |
0.80–2.0mm |
Ti-6Al-4V ELI, cold-worked or STA |
High strength in small diameters, fatigue resistance for cyclic loading |
|
Kirschner wires (K-wires), cerclage wires, external fixator pins |
1.0–3.0mm |
CP Grade 2 or Ti-6Al-4V |
Stiffness for fracture stabilization, ease of bending intraoperatively |
|
Formed wire structures - cages, frames, custom implants |
2.0–6.0mm |
Ti-6Al-4V, solution-treated or annealed |
Formability before final heat treatment, then strength after aging |
What the Certificate Should Actually Say
Every spool of medical titanium wire should ship with documentation. Here is what we provide and what you should demand:
|
Document Element |
Why It Matters |
Red Flags |
|
Heat number & melt method |
Traceability to the ingot; VAR or EB melting for medical grades |
No heat number, or "mixed heat" without justification |
|
Chemical composition - full, not just Ti |
Interstitial elements (O, H, C, N) drive mechanical properties and biocompatibility |
Omitted interstitial data, or "typical values" instead of actual lot analysis |
|
Mechanical properties - tensile, yield, elongation |
Confirms temper and drawing process control |
Only tensile reported; no yield or elongation |
|
Diameter measurement - actual, not nominal |
Drawing process control; affects your forming and coating processes |
Stated as "per spec" without actual measured values |
|
Surface condition & cleanliness |
Impacts coating adhesion, biocompatibility, and sterilization compatibility |
Vague terms like "clean" without test method reference |
|
Coil set / straightness data |
Critical for automated processing of fine wire |
No data, or "visually straight" |
The China Supply Reality
We are based in Baoji, Shaanxi - China's titanium valley. The wire drawing infrastructure here is extensive, but medical-grade capability is not evenly distributed.
|
Capability Level |
What You Get |
Typical Price Tier |
Risk Profile |
|
General industrial wire drawing |
CP titanium, basic surface, limited cert data |
Lowest |
High - inconsistent diameter, unknown melt source, limited traceability |
|
Aerospace-grade wire drawing |
Better diameter control, full certs, known melt source |
Medium |
Moderate - mechanically sound, but not always biocompatible surface finish |
|
Dedicated medical wire drawing |
Implant-grade alloys, validated cleaning, full traceability, process validation |
Higher |
Low - what you specify is what you get, documented and repeatable |
The gap between "aerospace-grade" and "medical-grade" is real and often underestimated. Aerospace wire can be mechanically perfect but biologically problematic - surface chemistry optimized for fatigue life rather than cell adhesion, lubricant residues acceptable for jet engines but not for implants.
Our approach: we source from mills with dedicated medical wire drawing lines, not general-purpose facilities that "also do medical." The segregation of tooling, lubricants, cleaning processes, and inspection equipment matters. Cross-contamination from industrial to medical is a risk we do not take.
Practical Sourcing Advice
Do not over-specify alloy. CP Grade 2 works for most non-load-bearing applications. Ti-6Al-4V ELI is necessary for fatigue-critical implants but adds cost and processing difficulty. β-titanium is exciting but still limited in supplier base and standardization.
Specify diameter with tolerance, not just nominal size. "1.0mm wire" is meaningless. "1.0mm ±0.005mm, measured at three points along each 500mm length" is a specification your supplier can meet and you can verify.
Ask about drawing lubricant and cleaning. Medical wire should be drawn with lubricants compatible with subsequent cleaning and sterilization. Some industrial lubricants leave residues that interfere with anodization or coating adhesion.
Request a process validation report for new suppliers. Not a certificate - a report showing how they established that their process consistently produces wire meeting your spec. This is standard practice for medical device manufacturers; it should be standard practice for their material suppliers too.
Plan for lead time. Medical wire, especially in fine diameters or specialized alloys, is not sitting on shelves. Drawing, annealing, cleaning, inspection, and certification take time. Rush orders compromise process control. Four to six weeks is realistic for standard sizes; eight to twelve weeks for specialized alloys or tight tolerances is not unusual.
What we actually ship
CP Grade 1 through 4, Ti-6Al-4V, Ti-6Al-4V ELI, and β-titanium on request
0.05mm to 6.0mm, with tolerances matched to your process
Tempers from fully annealed to spring temper
Surface: bright annealed, pickled, ground, or prepped for coating
Forms: spools, coils, straight lengths, cut-to-length
Documentation: full MTC with everything you need - chemistry, tensile, dimensions, surface, heat traceability. Custom reports if you ask.
Common sizes sit on the shelf for samples and small-batch orders. Production volume runs against your forecast and quality agreement. If you are qualifying suppliers, switching alloys, or in development, we will send specs, certificates, and samples. No filler - just the information you need.

Shaanxi Mingtai Dingsheng Metal Material Co., Ltd
Medical Titanium Alloy Materials | Wire, Bar, Plate & Custom Forms
Tel: +86 17391509251
Email: kristy@mt-titanium.com
Address: Room 103, Building 53, Gaoyi Industrial Park, Baqiu Town, High-tech Development Zone, Baoji City, Shaanxi Province, China