What it is
Car crash. Bad fall. Sports injury. Bone breaks. Sometimes into multiple pieces. Needs something to hold everything together while it heals.
This plate does that.
Orthopedic trauma titanium plate sits on the bone. Screws go through it into the bone. The fracture stays stable. The patient heals.
Femur. Tibia. Humerus. Radius. Pelvis. Any bone that takes load and needs strong fixation.
Titanium vs steel
Steel plates work. They've been used for decades. But steel has problems. Heavy. Causes artifacts on X-ray and CT. Contains nickel. Some patients react.
Titanium is different. About half the weight. No corrosion inside the body. No nickel. Cleaner imaging. Grade 23 ELI titanium delivers 860 MPa tensile strength - higher than most surgical steels pound for pound.
For a femur fracture or a tibial plateau, you need that strength. Orthopedic trauma titanium plate gives it to you with less material and less hassle.
Material specs
| Property | Value |
| Standard | ASTM F136 / ISO 5832-3 |
| Tensile (min) | 860 MPa |
| Yield (min) | 795 MPa |
| Elongation | ≥ 10% |
| Density | 4.43 g/cm³ |
Sizes by application
| Bone | Thickness | Width | Typical screw size |
| Distal radius | 1.5 – 2.0mm | 8 – 12mm | 2.4mm / 2.7mm |
| Humerus | 2.5 – 3.5mm | 10 – 15mm | 3.5mm |
| Tibial plateau | 2.5 – 4.0mm | 12 – 18mm | 3.5mm / 5.0mm |
| Distal femur | 3.5 – 4.5mm | 12 – 18mm | 5.0mm |
| Femoral shaft | 4.0 – 4.5mm | 15 – 20mm | 4.5mm / 5.0mm |
| Pelvis | 2.0 – 3.5mm | 10 – 16mm | 3.5mm |
Where it goes
Distal radius. Wrist fracture. Fall on an outstretched hand. One of the most common fractures in orthopedics. A 1.5mm or 2.0mm plate goes on the volar side. Low profile. Patient moves wrist early.
Tibial plateau. Top of the shin bone. High energy injury - car vs pedestrian, fall from height. Axial load drives the femur down into the tibia. The bone splits. Needs a 3.0mm to 4.0mm locking plate. L-shaped. Fits the anatomy.
Femoral shaft. Thigh bone. Car crash or high fall. Long bone. Long plate. 4.0mm to 4.5mm thick. 12 to 20 holes. Many screws. Patient bears weight early.
Pelvis. Fractures from side impact. Curved plates. 2.0mm to 3.5mm thick. Screws go into iliac crest, pubic ramus, or sacrum.
Humerus. Upper arm. 2.5mm to 3.5mm plate. The radial nerve runs nearby. Plate placement is critical.
Each orthopedic trauma titanium plate is pre-contoured for its specific bone. The surgeon doesn't spend time bending. Less OR time. Less fatigue.



Locking plate technology
Not all plates are the same.
Locking plate. The screw hole has threads. The screw head locks into the plate. Creates a fixed-angle construct. The screws don't back out. The plate doesn't lose position.
When do you need locking? Osteoporotic bone - screws hold better. Comminuted fractures - multiple pieces need bridging without compressing. Periarticular fractures - near the joint, need angle stability.
Non-locking plate. Standard screw. Just clamps the plate down. Creates compression across the fracture. Good for simple transverse breaks. Good for healthy bone.
Most orthopedic trauma titanium plate designs today are combination plates. Locking holes and compression holes in the same implant. The surgeon chooses hole by hole.
Pre-contoured design
Bones aren't flat. A straight plate doesn't fit a curved bone.
Distal radius plate. Volar curve. Matches the palmar side of the wrist. Pre-contoured to avoid the tendons.
Tibial plateau plate. L-shaped. The short leg goes on the top of the tibia. The long leg goes down the shaft.
Femur plate. Curved along the anterior bow of the femoral shaft. Wider at the distal end for the condyles.
Pelvic plate. Curved to match the iliac crest. Or straight for the pubic ramus.
We supply plates flat or pre-contoured. Send a 3D model. We match your anatomy. OEM customers send us their designs. We manufacture to print.
Surface finish
Implants touch tissue. Muscle. Tendon. Skin. Rough plates cause irritation. Scarring. Patient discomfort.
Polished. Ra ≤ 0.2μm. Smooth. Bright. Minimal friction. Standard for most trauma plates.
Anodized. Electrochemical color finish. Blue for 1.5mm-2.0mm. Gold for 2.5mm-3.0mm. Purple for 3.5mm-4.0mm. Green for 4.5mm. Color coding serves a purpose - the OR staff grabs the right plate without checking thickness with a gauge.
Color wears off at screw holes during surgery. That's normal. Doesn't affect performance.
Locking screw technology
Locking plates need locking screws. Different from standard screws. The head has threads. Matches the threads in the plate hole.
Torque is critical. Too loose - screw backs out. Too tight - screw head strips. Most trauma systems use torque-limiting drivers. Click when you hit the right torque.
We supply plate blanks without holes. You drill and thread your own holes. Or we drill to your print. Hole position tolerance ±0.05mm.
Traceability
Trauma plates are medical devices. Class II or III. Regulatory audits happen. Paperwork matters.
Every orthopedic trauma titanium plate blank comes with:
Heat number. Traces back to the original melt. Mill test report. Full chemistry. ASTM F136 or ISO 5832-3 certificate. Tensile, yield, elongation results. Surface finish report if specified.
EN 10204 3.1 is standard. 3.2 available with third-party inspection. We keep samples from every heat. If your notified body audits, we have the backup.
RFQ
Q: Grade 23 ELI or Grade 4 for trauma plates?
A: Grade 23 ELI. No debate. Grade 4 pure titanium is 550 MPa. Not strong enough for load-bearing trauma. Femur and tibia need 860 MPa.
Q: What thickness for a distal radius plate?
A: 1.5mm to 2.0mm. Radius is a small bone. Thin plate works. Patient doesn't bear weight on wrist.
Q: What thickness for a femur plate?
A: 4.0mm to 4.5mm. Femur takes full body weight. Plus muscle forces. Needs a thick plate. Long screws.
Q: What certifications come with the plate stock?
A: ASTM F136 cert. MTR with heat number. Mechanicals. EN 10204 3.1. 3.2 available.
Bottom line
High-energy trauma needs strong hardware. Orthopedic trauma titanium plate delivers.
Grade 23 ELI. ASTM F136. 1.5mm to 4.5mm thick. Pre-contoured. Locking or non-locking. Polished or anodized.
From distal radius to femoral shaft. From tibial plateau to pelvis.
Contact
Need a quote on orthopedic trauma titanium plate? Send bone type, thickness, quantity, locking or non-locking, and any pre-contour requirements. Include a drawing for custom shapes. We'll reply within 24 hours.
Email: kristy@mt-titanium.com
WhatsApp: +86-17391509251
Hot Tags: orthopedic trauma titanium plate, China orthopedic trauma titanium plate manufacturers, suppliers, factory, Craniofacial Reconstruction Titanium Plate ASTM F67, Medical Titanium Plate ASTM F136 Orthopedic Implants, Minimally Invasive Surgery Titanium Fixation Plate, Orthopedic Trauma Titanium Plate, Ti 6Al 4V ELI Medical Plate for Surgical Implants, Titanium Implant Plate